Customization: | Available |
---|---|
Contact: | Contactless |
Output Signal Type: | Analog Type |
Still deciding? Get samples of US$ 0.00/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Symbol | Min. | Max. | Unit |
Storage Temp. | Ts | -55 | 175 | ºC |
Supply Voltage | VCC | 3.5 | 28 | V |
Output Cut-off Voltage | VO(off) | - | 25 | V |
Magnetic Induction | B | unlimited | unlimited | mT |
Output Current | IO | - | 50 | mA |
Parameter | Symbol | Min. | Max. | Unit |
Supply Voltage | VCC | 4.5 | 24 | V |
Operating Temp. | Ta | -55 | 150 | ºC |
Output Current | IO | - | 8 | mA |
Parameter | Symbol | Test Condition | Typ. | Max. | Unit |
Output Low level | VOL | VCC1=4.5, VCC2=24V, IO=25mA,B≥BOP | 0.2 | 0.4 | V |
Output High Level | VOH | VCC1=4.5, VCC2=24V, IO=25mA,B≤BRP | 23.5 | 24 | V |
Output Leakage Current | IOH | VCC2=24V,VCC1Open circuit | 0.1 | 10 | μA |
Supply Current | ICC | VCC1=24V,Vo Open circuit | 3.5 | 8 | mA |
Output Rise Edge Time | tR | VCC1=VCC2=12V, RL=1.2kΩ, CL=20pF |
125 | 150 | ns |
Output Fall Edge Time | tF | 60 | 80 | ns |
Parameter | Symbol | Min. | Typ. | Max. |
Operate Point | BOP | - | 3 | 5 |
Release Point | BRP | -5 | -3 | - |
Hysteresis ∣Operate point -Release Point∣ |
BH ∣BOP-BRP∣ |
3 | 6 | 10 |